{"_buckets": {"deposit": "4ab2a95f-6e2d-4462-8d47-b79947119783"}, "_deposit": {"created_by": 1, "id": "44324", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44324"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044324", "sets": ["1"]}, "author_link": ["440285", "440286", "440284"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003-04", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "343", "bibliographicPageStart": "335", "bibliographicVolumeNumber": "30", "bibliographic_titles": [{"bibliographic_title": "Nuclear Medicine and Biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have designed and constructed an automated device for the production of ultra-high specific activity 11C-labeled compounds via [11C]CH3I synthesized by the single pass I2 method. The optimum condition for the production of[11C]CH3I was determined to be 630degree C for oven-1 (reaction column), 50degree C for oven-2 (iodine column) and 50 ml/min for the He gas flow rate, and gave the maximum conversion ratio of [11C]CH3I,44%. [11C]Ro15-4513, known as an inverse agonist of the benzodiazepine receptor, was produced under optimized conditions. An i.v.injectable[11C]Ro15-4513 solution of 1500+/-490 MBq (n=6) with specific activity 4700+/-2500 GBq/mumol and a radiochemical purity of 98.2+/-2% was obtained automatically within 25 minutes (from EOB) by irradiating nitrogen gas containing 5% H2 with 18 MeV protons (14,2 MeV on target) at 20 muA for 20 minutes. The highest specific activity of 9700 GBq/mumol (at EOS) could be achieved,although the radiochemical purity was 92.4%. By the use of the ultra-high specific activity [11C]Ro15-4513,the super high affinity binding sites in the rat brain hippocampus could be clearly visualized even at the extremely low concentration of 0.66 pM Ro15-4513 by in vitro autoradiography.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0969-8051", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Noguchi, Junko"}], "nameIdentifiers": [{"nameIdentifier": "440284", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Kazutoshi"}], "nameIdentifiers": [{"nameIdentifier": "440285", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木 和年", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "440286", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Automated synthesis of the ultra high specific activity of [11C]Ro15-4513 and its application in an extremely low concentration region to an ARG study", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Automated synthesis of the ultra high specific activity of [11C]Ro15-4513 and its application in an extremely low concentration region to an ARG study"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44324", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-23"}, "publish_date": "2006-06-23", "publish_status": "0", "recid": "44324", "relation": {}, "relation_version_is_last": true, "title": ["Automated synthesis of the ultra high specific activity of [11C]Ro15-4513 and its application in an extremely low concentration region to an ARG study"], "weko_shared_id": -1}
Automated synthesis of the ultra high specific activity of [11C]Ro15-4513 and its application in an extremely low concentration region to an ARG study
https://repo.qst.go.jp/records/44324
https://repo.qst.go.jp/records/443241e5d0646-ce27-4c81-8e73-773d7952dfce
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-23 | |||||
タイトル | ||||||
タイトル | Automated synthesis of the ultra high specific activity of [11C]Ro15-4513 and its application in an extremely low concentration region to an ARG study | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Noguchi, Junko
× Noguchi, Junko× Suzuki, Kazutoshi× 鈴木 和年 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have designed and constructed an automated device for the production of ultra-high specific activity 11C-labeled compounds via [11C]CH3I synthesized by the single pass I2 method. The optimum condition for the production of[11C]CH3I was determined to be 630degree C for oven-1 (reaction column), 50degree C for oven-2 (iodine column) and 50 ml/min for the He gas flow rate, and gave the maximum conversion ratio of [11C]CH3I,44%. [11C]Ro15-4513, known as an inverse agonist of the benzodiazepine receptor, was produced under optimized conditions. An i.v.injectable[11C]Ro15-4513 solution of 1500+/-490 MBq (n=6) with specific activity 4700+/-2500 GBq/mumol and a radiochemical purity of 98.2+/-2% was obtained automatically within 25 minutes (from EOB) by irradiating nitrogen gas containing 5% H2 with 18 MeV protons (14,2 MeV on target) at 20 muA for 20 minutes. The highest specific activity of 9700 GBq/mumol (at EOS) could be achieved,although the radiochemical purity was 92.4%. By the use of the ultra-high specific activity [11C]Ro15-4513,the super high affinity binding sites in the rat brain hippocampus could be clearly visualized even at the extremely low concentration of 0.66 pM Ro15-4513 by in vitro autoradiography. | |||||
書誌情報 |
Nuclear Medicine and Biology 巻 30, p. 335-343, 発行日 2003-04 |
|||||