WEKO3
アイテム
{"_buckets": {"deposit": "f119dcc2-e7a7-4529-b640-6f0f429ed0d7"}, "_deposit": {"created_by": 1, "id": "44278", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44278"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044278", "sets": ["1"]}, "author_link": ["439855", "439856"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "73", "bibliographicPageStart": "67", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "放射線"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A tandem detector, which positively raises directional dependence for coming gamma-rays, has been developed for simultaneous measurement of directions and energies of coming gamma-rays. The detector has optically combined a cylindrical NaI(Tl), the same sized BGO scuntillator and a fitted photomultiplier tube at this order. Since lengths of crossing each scintillator are changed according to coming directions of gamma-rays, directions can be recognized by counting photopeaks on a spectrum made by the NaI(Tl) and the BGO scintillator and by obtaining the ratio of photopeak counts. It is also clear that energies can be easily measured, which are proportional to channels of photopeaks on the spectrum derived from the detector.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0285-3604", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "白川, 芳幸"}], "nameIdentifiers": [{"nameIdentifier": "439855", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "白川 芳幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "439856", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "γ線の飛来方向とエネルギーの同時測定用タンデム検出器の開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "γ線の飛来方向とエネルギーの同時測定用タンデム検出器の開発"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44278", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-19"}, "publish_date": "2006-06-19", "publish_status": "0", "recid": "44278", "relation": {}, "relation_version_is_last": true, "title": ["γ線の飛来方向とエネルギーの同時測定用タンデム検出器の開発"], "weko_shared_id": -1}
γ線の飛来方向とエネルギーの同時測定用タンデム検出器の開発
https://repo.qst.go.jp/records/44278
https://repo.qst.go.jp/records/442782561ba8e-fb67-464f-8386-29e4dff78dda
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-19 | |||||
タイトル | ||||||
タイトル | γ線の飛来方向とエネルギーの同時測定用タンデム検出器の開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
白川, 芳幸
× 白川, 芳幸× 白川 芳幸 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A tandem detector, which positively raises directional dependence for coming gamma-rays, has been developed for simultaneous measurement of directions and energies of coming gamma-rays. The detector has optically combined a cylindrical NaI(Tl), the same sized BGO scuntillator and a fitted photomultiplier tube at this order. Since lengths of crossing each scintillator are changed according to coming directions of gamma-rays, directions can be recognized by counting photopeaks on a spectrum made by the NaI(Tl) and the BGO scintillator and by obtaining the ratio of photopeak counts. It is also clear that energies can be easily measured, which are proportional to channels of photopeaks on the spectrum derived from the detector. | |||||
書誌情報 |
放射線 巻 26, p. 67-73, 発行日 2000-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0285-3604 |