量研学術機関リポジトリ「QST-Repository」は、国立研究開発法人 量子科学技術研究開発機構に所属する職員等が生み出した学術成果(学会誌発表論文、学会発表、研究開発報告書、特許等)を集積しインターネット上で広く公開するサービスです。 Welcome to QST-Repository where we accumulates and discloses the academic research results(Journal Publications, Conference presentation, Research and Development Report, Patent, etc.) of the members of National Institutes for Quantum Science and Technology.
Thank you very much for using our website. On the 11th of March 2019, this site was moved from our own network server to the JAIRO Cloud network server. If you previously bookmarked this site, that bookmark will no longer work. We would be grateful if you could bookmark the website again. Thank you very much for your understanding and cooperation.
A newly developed rf buncher has been installed in the beam transport line of an electron cyclotron resonance (ECR) ion source, HiECR, at the Center for Nuclear Study (CNS) of the University of Tokyo. The rf buncher is a compact cavity having magnetic alloy (MA) cores and operates in the wide frequency range between 18 and 45 MHz without any tuning systems. Bunched beams of H+, O5+, and Ar8+ ions have been produced successfully and measured using a newly designed Faraday cup with good time resolution. In this paper, the design of the MA-loaded buncher cavity and the results of the beam test are presented. A detailed description of the HiECR beam transport line and the design of the new Faraday cup are also given.