WEKO3
アイテム
{"_buckets": {"deposit": "d2d4cafc-dde3-4c93-a6c1-8281f10fd699"}, "_deposit": {"created_by": 1, "id": "44132", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44132"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044132", "sets": ["1"]}, "author_link": ["438647", "438642", "438648", "438636", "438641", "438644", "438646", "438638", "438645", "438643", "438640", "438637", "438639"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1999-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "145", "bibliographicPageStart": "142", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "胸部CT検診"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "車載型らせんCTによる肺癌一次検診施行における、読影および判定時での問題点を検討し、それに対する対策として、CT検診比較読影システムの開発および試用を行った。複数年度のCT検診画像データを比較読影システムに変換・転送・保存することにより、読影時における読影医の負担の軽減および能率の向上が得られた。また、過去に撮像したCT画像との比較読影を行うことにより、より精度の高い判定を行いうると考えられた。", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1341-8556", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "潤間, 隆宏"}], "nameIdentifiers": [{"nameIdentifier": "438636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長尾, 啓一"}], "nameIdentifiers": [{"nameIdentifier": "438637", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "滝口, 裕一"}], "nameIdentifiers": [{"nameIdentifier": "438638", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "栗山, 蕎之"}], "nameIdentifiers": [{"nameIdentifier": "438639", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 公典"}], "nameIdentifiers": [{"nameIdentifier": "438640", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "志村, 昭光"}], "nameIdentifiers": [{"nameIdentifier": "438641", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤野, 雄一"}], "nameIdentifiers": [{"nameIdentifier": "438642", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 徹"}], "nameIdentifiers": [{"nameIdentifier": "438643", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福久, 健二郎"}], "nameIdentifiers": [{"nameIdentifier": "438644", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "438645", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "瀧口 裕一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438646", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438647", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福久 健二郎", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438648", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "CT検診比較読影システムの現場試用", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "CT検診比較読影システムの現場試用"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44132", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-06-01"}, "publish_date": "2006-06-01", "publish_status": "0", "recid": "44132", "relation": {}, "relation_version_is_last": true, "title": ["CT検診比較読影システムの現場試用"], "weko_shared_id": -1}
CT検診比較読影システムの現場試用
https://repo.qst.go.jp/records/44132
https://repo.qst.go.jp/records/44132b073ea82-ea22-4a2a-b24a-8c7b17b28737
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-06-01 | |||||
タイトル | ||||||
タイトル | CT検診比較読影システムの現場試用 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
潤間, 隆宏
× 潤間, 隆宏× 長尾, 啓一× 滝口, 裕一× 栗山, 蕎之× 鈴木, 公典× 志村, 昭光× 藤野, 雄一× 松本, 徹× 福久, 健二郎× その他× 瀧口 裕一× 松本 徹× 福久 健二郎 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 車載型らせんCTによる肺癌一次検診施行における、読影および判定時での問題点を検討し、それに対する対策として、CT検診比較読影システムの開発および試用を行った。複数年度のCT検診画像データを比較読影システムに変換・転送・保存することにより、読影時における読影医の負担の軽減および能率の向上が得られた。また、過去に撮像したCT画像との比較読影を行うことにより、より精度の高い判定を行いうると考えられた。 | |||||
書誌情報 |
胸部CT検診 巻 6, 号 2, p. 142-145, 発行日 1999-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1341-8556 |