WEKO3
アイテム
{"_buckets": {"deposit": "df320cdb-4f56-4172-8c0b-04df354849d9"}, "_deposit": {"created_by": 1, "id": "44108", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44108"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044108", "sets": ["1"]}, "author_link": ["438447", "438451", "438443", "438444", "438446", "438449", "438452", "438450", "438445", "438448"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "83", "bibliographicPageStart": "78", "bibliographicVolumeNumber": "7", "bibliographic_titles": [{"bibliographic_title": "胸部CT検診"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "肺がん検診用X線CTシステム(LSCT)の診断支援を目的として、肺がん病巣候補自動抽出における候補領域の詳細解析の改良を行った。がん陰影の抽出対象サイズを直径10mm異常から5mm以上に変更することにより直径10mm未満の偽陽性陰影が激増する。この削減のため、特徴量を用いた定量化によるFP削減アルゴリズムの開発を行った。このアルゴリズムを23症例に適用した結果、1症例当たりのFP数を約6.5個にすることができ、FP削減処理として良好な結果を得た。", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1341-8556", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "滝沢, 穂高"}], "nameIdentifiers": [{"nameIdentifier": "438443", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本, 眞司"}], "nameIdentifiers": [{"nameIdentifier": "438444", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 徹"}], "nameIdentifiers": [{"nameIdentifier": "438445", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野, 之男"}], "nameIdentifiers": [{"nameIdentifier": "438446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯沼, 武"}], "nameIdentifiers": [{"nameIdentifier": "438447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 満臣"}], "nameIdentifiers": [{"nameIdentifier": "438448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "その他"}], "nameIdentifiers": [{"nameIdentifier": "438449", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本 徹", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438450", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "舘野 之男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438451", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯沼 武", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "438452", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "胸部X線CT像の診断支援システムにおける肺がん病巣候補領域の治療的解析", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "胸部X線CT像の診断支援システムにおける肺がん病巣候補領域の治療的解析"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44108", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-05-30"}, "publish_date": "2006-05-30", "publish_status": "0", "recid": "44108", "relation": {}, "relation_version_is_last": true, "title": ["胸部X線CT像の診断支援システムにおける肺がん病巣候補領域の治療的解析"], "weko_shared_id": -1}
胸部X線CT像の診断支援システムにおける肺がん病巣候補領域の治療的解析
https://repo.qst.go.jp/records/44108
https://repo.qst.go.jp/records/441082755c4ef-fb61-4acd-b73d-16e5b0522dbf
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-05-30 | |||||
タイトル | ||||||
タイトル | 胸部X線CT像の診断支援システムにおける肺がん病巣候補領域の治療的解析 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
滝沢, 穂高
× 滝沢, 穂高× 山本, 眞司× 松本, 徹× 舘野, 之男× 飯沼, 武× 松本, 満臣× その他× 松本 徹× 舘野 之男× 飯沼 武 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 肺がん検診用X線CTシステム(LSCT)の診断支援を目的として、肺がん病巣候補自動抽出における候補領域の詳細解析の改良を行った。がん陰影の抽出対象サイズを直径10mm異常から5mm以上に変更することにより直径10mm未満の偽陽性陰影が激増する。この削減のため、特徴量を用いた定量化によるFP削減アルゴリズムの開発を行った。このアルゴリズムを23症例に適用した結果、1症例当たりのFP数を約6.5個にすることができ、FP削減処理として良好な結果を得た。 | |||||
書誌情報 |
胸部CT検診 巻 7, 号 2, p. 78-83, 発行日 2000-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1341-8556 |