{"_buckets": {"deposit": "e93b1fd9-b5f0-4967-a26b-28d8b76d0e62"}, "_deposit": {"created_by": 1, "id": "44014", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44014"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044014", "sets": ["1"]}, "author_link": ["437433", "437429", "437430", "437434", "437432", "437431", "437428"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "630", "bibliographicPageStart": "627", "bibliographicVolumeNumber": "72", "bibliographic_titles": [{"bibliographic_title": "Transplantation"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "BACKGROUND: 31P-magnetic resonance spectroscopy (MRS) has been widely used to study pretransplantation renal viability, and although some had discussed posttransplant renal viability, no one has examined long-term posttransplant renal prognosis. We discuss the use of 31P-MRS to assess the long-term prognosis from the time when MRS was performed. METHODS: We studied 20 patients with renal allografts. 1.5 Tesla clinical magnetic resonance imaging (MRI) and 15 cm surface coil was used for 31P-MRS. Localized 31P-MRS was done using image selected in vivo spectroscopy (ISIS) method. Individual peaks were fitted by Lorenzian line-shapes with a least square method and peak area ratios were calculated. RESULTS: A beta-adenosine triphosphate/inorganic phosphate (beta-ATP/Pi) ratio \u003e1.2 had sensitivity of 92.8%, specificity of 100%, and accuracy of 95% for predicting 3-year renal survival; a beta-ATP/Pi ratio \u003e1.2 had sensitivity of 90.9%, specificity of 66.7%, and accuracy of 76.9% for predicting 5-year renal survival. We compared 31P-MRS spectra data between the survived group and failed group. The survived group had significantly higher beta-ATP/Pi, alpha-ATP/Pi, and phosphodiester (PDE)/Pi ratios than the failed group. CONCLUSIONS: We discussed the beta-ATP/Pi value as a parameter for predicting long-term survival of a transplanted kidney from the time when MRS was performed. A value above 1.2 suggests a high probability of 3-year renal survival, whereas a value over 2.5 indicates that the transplanted kidney could survive over 5 years. 31P-MRS may be useful for predicting long-term survival of transplanted kidneys, but additional studies are needed.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0041-1337", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ikehira, Hiroo"}], "nameIdentifiers": [{"nameIdentifier": "437428", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "437429", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanada, Shuji"}], "nameIdentifiers": [{"nameIdentifier": "437430", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "437431", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "池平 博夫", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "437432", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "437433", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "棚田 修二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "437434", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Long-term assessment of posttransplant renal prognosis with 31P magnetic resonance spectroscopy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Long-term assessment of posttransplant renal prognosis with 31P magnetic resonance spectroscopy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44014", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-03-15"}, "publish_date": "2006-03-15", "publish_status": "0", "recid": "44014", "relation": {}, "relation_version_is_last": true, "title": ["Long-term assessment of posttransplant renal prognosis with 31P magnetic resonance spectroscopy"], "weko_shared_id": -1}
Long-term assessment of posttransplant renal prognosis with 31P magnetic resonance spectroscopy
https://repo.qst.go.jp/records/44014
https://repo.qst.go.jp/records/4401410923b0a-54a6-4325-85d1-d6ba23b54847
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-03-15 | |||||
タイトル | ||||||
タイトル | Long-term assessment of posttransplant renal prognosis with 31P magnetic resonance spectroscopy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ikehira, Hiroo
× Ikehira, Hiroo× Obata, Takayuki× Tanada, Shuji× et.al× 池平 博夫× 小畠 隆行× 棚田 修二 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | BACKGROUND: 31P-magnetic resonance spectroscopy (MRS) has been widely used to study pretransplantation renal viability, and although some had discussed posttransplant renal viability, no one has examined long-term posttransplant renal prognosis. We discuss the use of 31P-MRS to assess the long-term prognosis from the time when MRS was performed. METHODS: We studied 20 patients with renal allografts. 1.5 Tesla clinical magnetic resonance imaging (MRI) and 15 cm surface coil was used for 31P-MRS. Localized 31P-MRS was done using image selected in vivo spectroscopy (ISIS) method. Individual peaks were fitted by Lorenzian line-shapes with a least square method and peak area ratios were calculated. RESULTS: A beta-adenosine triphosphate/inorganic phosphate (beta-ATP/Pi) ratio >1.2 had sensitivity of 92.8%, specificity of 100%, and accuracy of 95% for predicting 3-year renal survival; a beta-ATP/Pi ratio >1.2 had sensitivity of 90.9%, specificity of 66.7%, and accuracy of 76.9% for predicting 5-year renal survival. We compared 31P-MRS spectra data between the survived group and failed group. The survived group had significantly higher beta-ATP/Pi, alpha-ATP/Pi, and phosphodiester (PDE)/Pi ratios than the failed group. CONCLUSIONS: We discussed the beta-ATP/Pi value as a parameter for predicting long-term survival of a transplanted kidney from the time when MRS was performed. A value above 1.2 suggests a high probability of 3-year renal survival, whereas a value over 2.5 indicates that the transplanted kidney could survive over 5 years. 31P-MRS may be useful for predicting long-term survival of transplanted kidneys, but additional studies are needed. | |||||
書誌情報 |
Transplantation 巻 72, 号 4, p. 627-630, 発行日 2001-08 |
|||||