WEKO3
アイテム
{"_buckets": {"deposit": "bdd51a9a-1a08-44af-bc2a-20bd9741058b"}, "_deposit": {"created_by": 1, "id": "43836", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43836"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043836", "sets": ["1"]}, "author_link": ["435811", "435807", "435808", "435814", "435813", "435812", "435815", "435817", "435806", "435809", "435816", "435810"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "82", "bibliographicPageStart": "79", "bibliographicVolumeNumber": "240", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments \u0026 Methods in Physics Research Section B"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A rotating gantry has been a popular tool for a radiation cancer therapy. However, the heavy-ion gantry is huge and expensive, because of the higher magnetic rigidity than that of a proton beam. As one of the downsizing methods, the field strength of a wobbling magnet for a uniform lateral-dose distribution should be increased. Since the field strength of the conventional wobbler is limited by an eddy-current effect under an operation frequency of around 50 Hz, we propose a new wobbling technique by rotating a pair of permanent magnets with a high magnetic field of around 2 T. For\ncarbon-ion therapy, the proposed technique reduces the irradiation-port length considerably to around 2 m from more\nthan 6 m in the conventional-gantry design.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-583X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kitagawa, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "435806", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Muramatsu, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "435807", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satou, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "435808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suda, Mitsuru"}], "nameIdentifiers": [{"nameIdentifier": "435809", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Noda, Kouji"}], "nameIdentifiers": [{"nameIdentifier": "435810", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "435811", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北川 敦志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435812", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松 正幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435813", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 眞二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435814", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "須田 充", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435815", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "野田 耕司", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435816", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435817", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "New medical irradiation technique by the permanent magnet system for the heavy-ion therapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "New medical irradiation technique by the permanent magnet system for the heavy-ion therapy"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43836", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-10-22"}, "publish_date": "2005-10-22", "publish_status": "0", "recid": "43836", "relation": {}, "relation_version_is_last": true, "title": ["New medical irradiation technique by the permanent magnet system for the heavy-ion therapy"], "weko_shared_id": -1}
New medical irradiation technique by the permanent magnet system for the heavy-ion therapy
https://repo.qst.go.jp/records/43836
https://repo.qst.go.jp/records/43836dcec41da-68ce-4ae2-8d1c-98e5cdf69a59
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-10-22 | |||||
タイトル | ||||||
タイトル | New medical irradiation technique by the permanent magnet system for the heavy-ion therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kitagawa, Atsushi
× Kitagawa, Atsushi× Muramatsu, Masayuki× Satou, Shinji× Suda, Mitsuru× Noda, Kouji× Kanai, Tatsuaki× 北川 敦志× 村松 正幸× 佐藤 眞二× 須田 充× 野田 耕司× 金井 達明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A rotating gantry has been a popular tool for a radiation cancer therapy. However, the heavy-ion gantry is huge and expensive, because of the higher magnetic rigidity than that of a proton beam. As one of the downsizing methods, the field strength of a wobbling magnet for a uniform lateral-dose distribution should be increased. Since the field strength of the conventional wobbler is limited by an eddy-current effect under an operation frequency of around 50 Hz, we propose a new wobbling technique by rotating a pair of permanent magnets with a high magnetic field of around 2 T. For carbon-ion therapy, the proposed technique reduces the irradiation-port length considerably to around 2 m from more than 6 m in the conventional-gantry design. |
|||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section B 巻 240, p. 79-82, 発行日 2005-11 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X |