WEKO3
アイテム
{"_buckets": {"deposit": "f54ece50-2004-4981-a7c1-2bce04415947"}, "_deposit": {"created_by": 1, "id": "43815", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43815"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043815", "sets": ["1"]}, "author_link": ["435621", "435619", "435615", "435616", "435618", "435617", "435614", "435620", "435622"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "12", "bibliographicPageStart": "3", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "医学物理"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The kinematics of boron compounds in vivo is crucial to the boron neutron capture therapy. In this paper, we proposed the prompt gamma-ray Compton scatter camera (PG-CSC), which can evaluate the 3-D kinematics of boron compounds without invasion. This PG-CSC combines a Compton camera with the prompt gamma-ray analysis. The results of its design optimization and tests with simulations, showed that one-hour-measurement was enough for evaluating a 3-D boron concentration distribution in a rat\u0027s brain with the resolution of 1mm in FWHM.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1345-5354", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "石川, 正純"}], "nameIdentifiers": [{"nameIdentifier": "435614", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平澤, 雅彦"}], "nameIdentifiers": [{"nameIdentifier": "435615", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "富谷, 武浩"}], "nameIdentifiers": [{"nameIdentifier": "435616", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山, 秀雄"}], "nameIdentifiers": [{"nameIdentifier": "435617", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "星, 正治"}], "nameIdentifiers": [{"nameIdentifier": "435618", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平澤 雅彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435619", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "富谷 武浩", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435620", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村山 秀雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435621", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "星 正治", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435622", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "非侵襲的ホウ素濃度分布測定システムの基礎的検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "非侵襲的ホウ素濃度分布測定システムの基礎的検討"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43815", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-10-13"}, "publish_date": "2005-10-13", "publish_status": "0", "recid": "43815", "relation": {}, "relation_version_is_last": true, "title": ["非侵襲的ホウ素濃度分布測定システムの基礎的検討"], "weko_shared_id": -1}
非侵襲的ホウ素濃度分布測定システムの基礎的検討
https://repo.qst.go.jp/records/43815
https://repo.qst.go.jp/records/438151aa612b8-1f15-43e5-9b16-4dc5652d3d8a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-10-13 | |||||
タイトル | ||||||
タイトル | 非侵襲的ホウ素濃度分布測定システムの基礎的検討 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
石川, 正純
× 石川, 正純× 平澤, 雅彦× 富谷, 武浩× 村山, 秀雄× 星, 正治× 平澤 雅彦× 富谷 武浩× 村山 秀雄× 星 正治 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The kinematics of boron compounds in vivo is crucial to the boron neutron capture therapy. In this paper, we proposed the prompt gamma-ray Compton scatter camera (PG-CSC), which can evaluate the 3-D kinematics of boron compounds without invasion. This PG-CSC combines a Compton camera with the prompt gamma-ray analysis. The results of its design optimization and tests with simulations, showed that one-hour-measurement was enough for evaluating a 3-D boron concentration distribution in a rat's brain with the resolution of 1mm in FWHM. | |||||
書誌情報 |
医学物理 巻 25, 号 1, p. 3-12, 発行日 2005-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1345-5354 |