{"_buckets": {"deposit": "f8e9b553-f679-4aa2-9bcc-5f0fbd65a56c"}, "_deposit": {"created_by": 1, "id": "43798", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43798"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043798", "sets": ["1"]}, "author_link": ["435440", "435444", "435439", "435445", "435446", "435449", "435453", "435442", "435448", "435452", "435451", "435438", "435443", "435447", "435450", "435441"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "284", "bibliographicPageStart": "270", "bibliographicVolumeNumber": "222", "bibliographic_titles": [{"bibliographic_title": "Nuclear Instruments \u0026 Methods in Physics Research Section B"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Due to the favorable characteristics of heavy-ion beams such as dose localization as well as high relative biological effectiveness, heavy-ion cancer therapy is attracting growing interests all over the world. The application of beta-delayed particle decay beams like 9C ions in cancer therapy is expected to further improve the treatment efficacy of the modality of heavy-ions. For the first time 9C beams were produced in the secondary beam line (SBL) of the HIMAC facility with a primary 12C beam of 430 MeV/n. The production conditions providing a 9C beam with higher production rate and purity were optimized using different thick production targets and degraders. The results show setting the momentum acceptance to the full value of 5% the production rate is 9.07 x 10^-6^ and the purity is 82.88% for the produced 9C beam under the optimal condition. Because of the large momentum spread for a secondary beam, the momentum distribution of the produced 9C beam at the optimal condition was measured. The momentum among the beam had a nearly Gaussian profile with a standard deviation of 26.1 MeV/c/n and the largest component of the momenta appeared around 838.9 MeV/c/n. In order to form a relatively large uniform irradiation field being apppropriate to further biologicl experiments for the produced 9C beam, the scanning magnets in the irradiation system of the SBL, operating in a wobbling mode, was use. A uniform irradiation field of 20 mm in diameter could be achieved with homogeneity of 93.3%. The work presented in this paper provides a substantial basis for the further studies with 9C beams for the therapeutic purpose.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0168-583X", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Li, Qiang"}], "nameIdentifiers": [{"nameIdentifier": "435438", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitagawa, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "435439", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanai, Tatsuaki"}], "nameIdentifiers": [{"nameIdentifier": "435440", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanazawa, Mitsutaka"}], "nameIdentifiers": [{"nameIdentifier": "435441", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Urakabe, Eriko"}], "nameIdentifiers": [{"nameIdentifier": "435442", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tomitani, Takehiro"}], "nameIdentifiers": [{"nameIdentifier": "435443", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Satou, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "435444", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhang, Wei"}], "nameIdentifiers": [{"nameIdentifier": "435445", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "李 強", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北川 敦志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金井 達明", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金澤 光隆", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435449", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "新谷 恵理子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435450", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "富谷 武浩", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435451", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤 眞二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435452", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "張 偉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435453", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Therapeutic purpose 9C beams produced in the secondary beam line at HIMAC", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Therapeutic purpose 9C beams produced in the secondary beam line at HIMAC"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43798", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-09-13"}, "publish_date": "2005-09-13", "publish_status": "0", "recid": "43798", "relation": {}, "relation_version_is_last": true, "title": ["Therapeutic purpose 9C beams produced in the secondary beam line at HIMAC"], "weko_shared_id": -1}
Therapeutic purpose 9C beams produced in the secondary beam line at HIMAC
https://repo.qst.go.jp/records/43798
https://repo.qst.go.jp/records/437986bd85636-b09e-412b-8fe0-4c9bba656953
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-09-13 | |||||
タイトル | ||||||
タイトル | Therapeutic purpose 9C beams produced in the secondary beam line at HIMAC | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Li, Qiang
× Li, Qiang× Kitagawa, Atsushi× Kanai, Tatsuaki× Kanazawa, Mitsutaka× Urakabe, Eriko× Tomitani, Takehiro× Satou, Shinji× Zhang, Wei× 李 強× 北川 敦志× 金井 達明× 金澤 光隆× 新谷 恵理子× 富谷 武浩× 佐藤 眞二× 張 偉 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Due to the favorable characteristics of heavy-ion beams such as dose localization as well as high relative biological effectiveness, heavy-ion cancer therapy is attracting growing interests all over the world. The application of beta-delayed particle decay beams like 9C ions in cancer therapy is expected to further improve the treatment efficacy of the modality of heavy-ions. For the first time 9C beams were produced in the secondary beam line (SBL) of the HIMAC facility with a primary 12C beam of 430 MeV/n. The production conditions providing a 9C beam with higher production rate and purity were optimized using different thick production targets and degraders. The results show setting the momentum acceptance to the full value of 5% the production rate is 9.07 x 10^-6^ and the purity is 82.88% for the produced 9C beam under the optimal condition. Because of the large momentum spread for a secondary beam, the momentum distribution of the produced 9C beam at the optimal condition was measured. The momentum among the beam had a nearly Gaussian profile with a standard deviation of 26.1 MeV/c/n and the largest component of the momenta appeared around 838.9 MeV/c/n. In order to form a relatively large uniform irradiation field being apppropriate to further biologicl experiments for the produced 9C beam, the scanning magnets in the irradiation system of the SBL, operating in a wobbling mode, was use. A uniform irradiation field of 20 mm in diameter could be achieved with homogeneity of 93.3%. The work presented in this paper provides a substantial basis for the further studies with 9C beams for the therapeutic purpose. | |||||
書誌情報 |
Nuclear Instruments & Methods in Physics Research Section B 巻 222, p. 270-284, 発行日 2004 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-583X |