WEKO3
アイテム
{"_buckets": {"deposit": "b70f9f7a-1c22-44ed-8874-bdf14559ff9c"}, "_deposit": {"created_by": 1, "id": "43789", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43789"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043789", "sets": ["1"]}, "author_link": ["435364", "435365", "435371", "435363", "435368", "435369", "435370", "435367", "435362", "435366"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "161", "bibliographicPageStart": "157", "bibliographicVolumeNumber": "79", "bibliographic_titles": [{"bibliographic_title": "日大歯学"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "摂食嚥下が困難な患者に対して、造影剤を含む液体または半固形・固形物を被験者に飲食させ、口への取り込みから嚥下の終了までの動態をX線透視装置と録画装置を用い記録・観察する方法にビデオ嚥下造営検査(Videofluorography,以下VF)がある。今回我々の行っているVF検査に伴う被曝線量について報告する。使用したX線透視装置はClearscope(Model SXT9000A,\n東芝)である。ファントムはX線人体等価のWoman Rando Phantom(Alderson)を使用した。測定にはUD-170A(BeO)およびUD-110S(Ca2SO4)(Panasonic)の熱蛍光線量計(TLD)を用いた。測定対象とした組織・臓器は生殖腺、赤色骨髄、甲状腺、肺、胃、結腸、肝臓、食道、膀胱、乳房、皮膚、脳、胸腺、副腎、腎臓、脾臓、膵臓、小腸、上部大腸、子宮、唾液腺(耳下腺・顎下腺、舌下腺)および水晶体であり、それぞれについて被曝線量を測定した。結果は以下のようであった。1.VF検査時の照射野", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-0102", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岩井, 一男"}], "nameIdentifiers": [{"nameIdentifier": "435362", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "橋本, 光二"}], "nameIdentifiers": [{"nameIdentifier": "435363", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "澤田, 久仁彦"}], "nameIdentifiers": [{"nameIdentifier": "435364", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 邦史"}], "nameIdentifiers": [{"nameIdentifier": "435365", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "里見, 智恵子"}], "nameIdentifiers": [{"nameIdentifier": "435366", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "生木, 俊輔"}], "nameIdentifiers": [{"nameIdentifier": "435367", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 光彦"}], "nameIdentifiers": [{"nameIdentifier": "435368", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西澤, かな枝"}], "nameIdentifiers": [{"nameIdentifier": "435369", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩井 一男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435370", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西澤 かな枝", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "435371", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ビデオ嚥下造影検査時の被曝線量", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ビデオ嚥下造影検査時の被曝線量"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43789", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-08-31"}, "publish_date": "2005-08-31", "publish_status": "0", "recid": "43789", "relation": {}, "relation_version_is_last": true, "title": ["ビデオ嚥下造影検査時の被曝線量"], "weko_shared_id": -1}
ビデオ嚥下造影検査時の被曝線量
https://repo.qst.go.jp/records/43789
https://repo.qst.go.jp/records/437897ed0435c-fe12-4618-bf46-882ad7d9ab52
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-08-31 | |||||
タイトル | ||||||
タイトル | ビデオ嚥下造影検査時の被曝線量 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
岩井, 一男
× 岩井, 一男× 橋本, 光二× 澤田, 久仁彦× 松本, 邦史× 里見, 智恵子× 生木, 俊輔× 松本, 光彦× 西澤, かな枝× 岩井 一男× 西澤 かな枝 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 摂食嚥下が困難な患者に対して、造影剤を含む液体または半固形・固形物を被験者に飲食させ、口への取り込みから嚥下の終了までの動態をX線透視装置と録画装置を用い記録・観察する方法にビデオ嚥下造営検査(Videofluorography,以下VF)がある。今回我々の行っているVF検査に伴う被曝線量について報告する。使用したX線透視装置はClearscope(Model SXT9000A, 東芝)である。ファントムはX線人体等価のWoman Rando Phantom(Alderson)を使用した。測定にはUD-170A(BeO)およびUD-110S(Ca2SO4)(Panasonic)の熱蛍光線量計(TLD)を用いた。測定対象とした組織・臓器は生殖腺、赤色骨髄、甲状腺、肺、胃、結腸、肝臓、食道、膀胱、乳房、皮膚、脳、胸腺、副腎、腎臓、脾臓、膵臓、小腸、上部大腸、子宮、唾液腺(耳下腺・顎下腺、舌下腺)および水晶体であり、それぞれについて被曝線量を測定した。結果は以下のようであった。1.VF検査時の照射野 |
|||||
書誌情報 |
日大歯学 巻 79, p. 157-161, 発行日 2005 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385-0102 |