WEKO3
アイテム
{"_buckets": {"deposit": "59f3ff04-1f6c-4e83-91cc-2c1f22a09bda"}, "_deposit": {"created_by": 1, "id": "43165", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "43165"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00043165", "sets": ["1"]}, "author_link": ["429452", "429457", "429463", "429454", "429455", "429462", "429458", "429459", "429451", "429453", "429461", "429460", "429456"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "11", "bibliographicPageEnd": "1060", "bibliographicPageStart": "1055", "bibliographicVolumeNumber": "78", "bibliographic_titles": [{"bibliographic_title": "International Journal of Radiation Biology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: To study the effects of high-energy carbon ion irradiation on negative gravitaxis in the photosynthetic flagellate Euglena gracilis strain Z in a dose-response-dependent manner.\nMaterials and methods: Cells were exposed to 290 MeV amu-1 carbon ion from the Heavy Ion Medical Accelerator in Chiba (HIMAC) at 12 doses (0, 1, 5, 7.5, 10, 15, 20, 50, 75, 100, 150, 200 Gy for water). Gamma was used to quantify negative gravitaxis observed in a recently developed biomonitoring system.\nResults: Negative gravitaxis of Euglena was significantly affected by irradiation at a dose \u003e 7.5 Gy, 28 h after irradiation. Negative gravitaxis recovered after a few days. The rising phase of gamma during the first 30s of orientation was independent of irradiation dose. The recovery mechanism itself was damaged by 290 MeV amu-1 carbon ions at a dose \u003e 50 Gy.\nConclutions: The results indicate that negative gravitaxis in Euglena may be affected by the radiation experienced during a space experiment especially during the occurrence of solar flares. The analyses of time needed to reorient to the gravitational vector suggest that the steering control of the flagellar apparatus is affected by exposure to the 290 MeV amu-1 carbon ion irradiation, resulting in an altered beating pattern of a flagellum and/or changes of the cell from during reorientation.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0955-3002", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sakashita, Tetsuya"}], "nameIdentifiers": [{"nameIdentifier": "429451", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Doi, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "429452", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yasuda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "429453", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takeda, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "429454", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fuma, Shoichi"}], "nameIdentifiers": [{"nameIdentifier": "429455", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamura, Yuuji"}], "nameIdentifiers": [{"nameIdentifier": "429456", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "P., Haeder Donat"}], "nameIdentifiers": [{"nameIdentifier": "429457", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂下 哲哉", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "429458", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "土居 雅広", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "429459", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "保田 浩志", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "429460", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武田 洋", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "429461", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "府馬 正一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "429462", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "中村 裕二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "429463", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "High-energy carbon ion irradiation inhibits negative gravitaxis in Euglena gracilis Z.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "High-energy carbon ion irradiation inhibits negative gravitaxis in Euglena gracilis Z."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/43165", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-10-17"}, "publish_date": "2003-10-17", "publish_status": "0", "recid": "43165", "relation": {}, "relation_version_is_last": true, "title": ["High-energy carbon ion irradiation inhibits negative gravitaxis in Euglena gracilis Z."], "weko_shared_id": -1}
High-energy carbon ion irradiation inhibits negative gravitaxis in Euglena gracilis Z.
https://repo.qst.go.jp/records/43165
https://repo.qst.go.jp/records/4316542a66c6d-7dd4-4676-af75-21d5a795b714
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-10-17 | |||||
タイトル | ||||||
タイトル | High-energy carbon ion irradiation inhibits negative gravitaxis in Euglena gracilis Z. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Sakashita, Tetsuya
× Sakashita, Tetsuya× Doi, Masahiro× Yasuda, Hiroshi× Takeda, Hiroshi× Fuma, Shoichi× Nakamura, Yuuji× P., Haeder Donat× 坂下 哲哉× 土居 雅広× 保田 浩志× 武田 洋× 府馬 正一× 中村 裕二 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: To study the effects of high-energy carbon ion irradiation on negative gravitaxis in the photosynthetic flagellate Euglena gracilis strain Z in a dose-response-dependent manner. Materials and methods: Cells were exposed to 290 MeV amu-1 carbon ion from the Heavy Ion Medical Accelerator in Chiba (HIMAC) at 12 doses (0, 1, 5, 7.5, 10, 15, 20, 50, 75, 100, 150, 200 Gy for water). Gamma was used to quantify negative gravitaxis observed in a recently developed biomonitoring system. Results: Negative gravitaxis of Euglena was significantly affected by irradiation at a dose > 7.5 Gy, 28 h after irradiation. Negative gravitaxis recovered after a few days. The rising phase of gamma during the first 30s of orientation was independent of irradiation dose. The recovery mechanism itself was damaged by 290 MeV amu-1 carbon ions at a dose > 50 Gy. Conclutions: The results indicate that negative gravitaxis in Euglena may be affected by the radiation experienced during a space experiment especially during the occurrence of solar flares. The analyses of time needed to reorient to the gravitational vector suggest that the steering control of the flagellar apparatus is affected by exposure to the 290 MeV amu-1 carbon ion irradiation, resulting in an altered beating pattern of a flagellum and/or changes of the cell from during reorientation. |
|||||
書誌情報 |
International Journal of Radiation Biology 巻 78, 号 11, p. 1055-1060, 発行日 2002 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0955-3002 |