WEKO3
アイテム
{"_buckets": {"deposit": "a172dfd1-50f5-4f5e-a762-2c3c00eb4252"}, "_deposit": {"created_by": 1, "id": "42921", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "42921"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00042921", "sets": ["1"]}, "author_link": ["427135", "427131", "427134", "427132", "427136", "427133", "427130", "427129"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "461", "bibliographicPageStart": "460", "bibliographicVolumeNumber": "27", "bibliographic_titles": [{"bibliographic_title": "Clinical Nuclear Medicine"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In pulmonary disease, the clearance of N-isopropyl-p-[I-123] iodoamphetamine (I-123 IMP) from the lung is prolonged, and retention of the tracer is noted in the pulmonary lesion as a result of damage to the pulmonary endothelium. A patient with acute pulmonary thromboembolism was examined using I-123 IMP pulmonary SPECT. The patient was treated with heparin after the early images were obtained but before the delayed images. The early images showed mildly reduced distribution of the tracer in the right lower lobe. Delayed images showed no retantion of the tracer. The findings indicate that pulmonary endothelial cells in a transient, pulmonary arterial hypoperfused area may remain intact.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0363-9762", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Watanabe, Naoyuki"}], "nameIdentifiers": [{"nameIdentifier": "427129", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanada, Shuji"}], "nameIdentifiers": [{"nameIdentifier": "427130", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Murata, Hajime"}], "nameIdentifiers": [{"nameIdentifier": "427131", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sasaki, Yasuhito"}], "nameIdentifiers": [{"nameIdentifier": "427132", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡辺 直行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "427133", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "棚田 修二", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "427134", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村田 啓", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "427135", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐々木 康人", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "427136", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "I-123 IMP Pulmonary SPECT in a Patient with Acute Pulmonary Thromboembolism", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "I-123 IMP Pulmonary SPECT in a Patient with Acute Pulmonary Thromboembolism"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/42921", "pubdate": {"attribute_name": "公開日", "attribute_value": "2002-06-10"}, "publish_date": "2002-06-10", "publish_status": "0", "recid": "42921", "relation": {}, "relation_version_is_last": true, "title": ["I-123 IMP Pulmonary SPECT in a Patient with Acute Pulmonary Thromboembolism"], "weko_shared_id": -1}
I-123 IMP Pulmonary SPECT in a Patient with Acute Pulmonary Thromboembolism
https://repo.qst.go.jp/records/42921
https://repo.qst.go.jp/records/42921d7035e9d-e549-4e52-98ca-9c502055d3e6
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2002-06-10 | |||||
タイトル | ||||||
タイトル | I-123 IMP Pulmonary SPECT in a Patient with Acute Pulmonary Thromboembolism | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Watanabe, Naoyuki
× Watanabe, Naoyuki× Tanada, Shuji× Murata, Hajime× Sasaki, Yasuhito× 渡辺 直行× 棚田 修二× 村田 啓× 佐々木 康人 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In pulmonary disease, the clearance of N-isopropyl-p-[I-123] iodoamphetamine (I-123 IMP) from the lung is prolonged, and retention of the tracer is noted in the pulmonary lesion as a result of damage to the pulmonary endothelium. A patient with acute pulmonary thromboembolism was examined using I-123 IMP pulmonary SPECT. The patient was treated with heparin after the early images were obtained but before the delayed images. The early images showed mildly reduced distribution of the tracer in the right lower lobe. Delayed images showed no retantion of the tracer. The findings indicate that pulmonary endothelial cells in a transient, pulmonary arterial hypoperfused area may remain intact. | |||||
書誌情報 |
Clinical Nuclear Medicine 巻 27, p. 460-461, 発行日 2002-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0363-9762 |